Barrier coatings are frequently employed on solid oral dosage forms under the assumption that they prevent moisture sorption into tablet cores thereby averting premature degradation of moisture-sensitive active ingredients. However, the efficacy of moisture barrier coatings remains unproven and they may actually accelerate degradation. This study aimed to investigate the barrier performance of four coating systems following application onto a low hygroscopic tablet formulation containing aspirin as a model moisture sensitive drug.